空调说明书

Hot water heat pump installation instructions

Thank you for using our Zhigao central air conditioners.

This instruction book is a general version of heat pump hot water machine from Zhigao.

The appearance of machine that you buy may be different from the instruction book we described. But it doesn’t matter for your operations.

Before you use it, please read the instruction book carefully and take care of it

The product you are using is air heat pump and water heater of Zhigao, it needs cleaning and maintaining periodically. If it is not done, the rate of breaking down would increase, and its life would reduce seriously; while if cleaned reasonably, the internal dust would be eliminated as result of improving indoor air quality, and reducing the power consumption.

To protect your legal rights, please install by qualified workers. .

The product you are using is heat pump and water heater of Zhigao. If it operates within a short time in winter, make sure charge for 24 hours a day; if not operates for a long time, be sure to draw off water in it, avoiding the unit’s cracking. Please contact with central air-conditioning management system center, Zhigao regularly, professionals will be sent with paying for checking, draining, adding water, adjustment and other cleaning and maintenance services. Just in case, air conditioner fails down.

Contents

1. 2. 3. 4. 5. 6. 7. 8. 9.

Measures of safety precautions … ……………………………………….. …………… Choosing places of installing…………………………………………………………… Installation of units……………………………………………………………………… Installation of wanderled controller…………………………………………………… Electrical connection ……………………………………………………………… Test of units’ working … …………………………………………………………… Protection and maintenances… ……………………………………………

Names of various part of unit and parameter…… ……………………………………… Instructions of unit function…………………………………………………………

10. Installation of available accessories………………………………………………

Closures chart 1 chart 2 chart 3

1. Measures of Safety Precautions Warning

Dealer or qualified installer is needed.

Installers should be qualified, if install by themselves. Incorrect operations will result in fire, electric shock, injury and leakage.

If the accessories are purchased locally, they should be designated.

Using the specified product may cause fire accidents such as electric shock , leakage. For retails,

professional installers are needed.

Power connections shall comply with the requirements of the local electric company.

By law, reliable grounding is needed. If the ground connection is imperfect, it may result in electric shock.

When the heat pump water heater needs to be moved or re-installed, contact your dealer or professional operators.

Improper installation will result in fire, electric shock, injury, leakage and other accidents. Don’t

make repairs by yourself.

Improper repairs can cause fire, electric shock, injury, leakage and other accidents, be sure to ask

your dealer or professionals for help.

Caution

1. Check the installation of leakage protection.

Leakage protection switch must be installed, if not, it may result in electric shock. 2.Connect the cable correctly.

If the cable is in the wrong way, it may damage the electrical components.

3.The unit can not be set in the combustibles (paint, gasoline, chemical reagents, etc.) near the operation to prevent the risk of fire or explosion. If caught a fire, please immediately turn off the power and put the fire out with a fire extinguisher.

4.Don ’t touch the refrigerant exhausting components to avoid being scalded.

According to the instructions, the unit is required regular maintained to ensure its working. If the unit fails to work, please find the fault and eliminate it ,according to the manual of the "Fault Analysis and Troubleshooting", or contact central air conditioning product management center, identify and eliminate causes of malfunction before rebooting; Don’t do in the case of failure without forcibly boot .

5.If the refrigerant or water happens to leak, please immediately turn off all switches,; For example, the unit can not be operated by the controller, you must turn off the main power to make it stop.

6.Please use the specified capacity fuse, do not use wire, copper wire instead , or it would caught a fire.

2-1 Choosing places for installing

1)Units can be installed on the ground or on a suitable roof, but make sure ventilate as much as possible.

2)Avoid units to be installed in which there’s certain requirements of noise and vibration. 3)The installing places should be avoided where has direct sun shining, and should be far away from the boiler flue or the air which will corrode copper condenser and coils. 4)If the units location are available to unauthorized people ,security measures should be taken, such as setting the fence and so on. This would prevent accidental damage or artificial breakage and it also would prevent the controlling box to be opened to expose the running electrical components

5)The base height of the unit installing should be no less than 100mm.Make sure there’s a drain to let water run out smoothly with no pounding.

6)When installing on the ground, the unit should be placed on a flat concrete base, which should be extended in the permafrost below. Do not place the base unit connecting with the building foundation to avoid noise and vibration transmitting to influence others. The base unit with mounting holes can be tightened with the unit.

7)When the unit is installed on the roof, steels of base units must be strong enough to support the weight of the crew and worker, the unit can be used to support a similar ground-mounted concrete foundation and channel frame. Load-bearing steel tanks with the unit damper mounting holes must be in the same center line, and has sufficient width to install.

8)For special occasional installation requirements , please consult an architect or building contractor or other professional advices.

Caution

When determine the installation positions, water pipes and wiring installation should be considered with no smoking, steaming or other heat draught. What’s more, working noises and cold or hot winds do not affect the surrounding.

2-2Tank installation site selection

1)Places of providing sufficient space for the installation and maintenance.

2)Supporting surface is flat, and can sustain the tank and be fixed to the tank at a vertical direction 3)Places of no corrosive gas leakage.

4)Places are easy to install plumbing and electrical connections

2 The suitable place for installing 2-3 Rooms for installation

1. When installing , resume some place for mending as the following chart, then install the unit

2.Make sure leave enough room for mending .

Pay Caution:

1.If there’s obstruct on the air conditioner unit, please put upper it more than 200mm.

2.If there’s piles of things around the unit , then the distance from its top should be 400 mm 3. If the air conditioner unit is settled in the underground,indoor ,or other closed places, please pay attention to the air circulation around the units , the volume of air for RS-200M/Y should be more than 8000m3/h, so is 12000m3/h for RS-380/TA.

2-4 The moving of air conditioner unit

1. Please use four steel wires of more than & 6mm hanging units to move in .

2. To avoid the units ’ surface to be scratched, deformed, please contact soft things on their

surface with the wire.

3.When it is over, please move away the transporting plate.

2-5 The moving of many air conditioner units

Chart 2.3 RS-200M/Y

Foundation bolts 4/table

Working distance of foundation bolts as the following chart

Chart

3 The units of installation

3-1 The connection of pipe

Caution

During the installing procession, air, dust, and other debris should be not allowed in the piping system. Water heater should be heated before installing inlet and outlet water pipe.

3-1-1 Heat insulation

Insulation materials must be equipped with outlet water pipe 1)Single heat pump water heater connection diagram

2)

multiple heat pump water heaters connection diagram

There are 32 heat pump water heaters at most can be connected one time.

1 cut-off valve 2 Solenoid valve 3. Check valve 4 filters (not less than 60 mesh) 5. Union 6 circulating pump 7. Pressure gauge 8. Thermometer 9. Flow switch 10. Auxiliary heating device (user selectable)

11. Collecting tank (requires higher circulating water outlet port) 12. Collecting tank purge valve 13. Use valve14 pressure switch in parallel flow switch T5: Radiator bulb S1, S2: collecting tank level switch Chart 3.2 RS-200M/Y the choosing of outlet pipe

RS-380M/Ta

the choosing of outlet pipe

并联机组数 the number of parallel units 进水管径 inlet diameter

出水管径outlet diameter

Hot water heat pump installation instructions

Thank you for using our Zhigao central air conditioners.

This instruction book is a general version of heat pump hot water machine from Zhigao.

The appearance of machine that you buy may be different from the instruction book we described. But it doesn’t matter for your operations.

Before you use it, please read the instruction book carefully and take care of it

The product you are using is air heat pump and water heater of Zhigao, it needs cleaning and maintaining periodically. If it is not done, the rate of breaking down would increase, and its life would reduce seriously; while if cleaned reasonably, the internal dust would be eliminated as result of improving indoor air quality, and reducing the power consumption.

To protect your legal rights, please install by qualified workers. .

The product you are using is heat pump and water heater of Zhigao. If it operates within a short time in winter, make sure charge for 24 hours a day; if not operates for a long time, be sure to draw off water in it, avoiding the unit’s cracking. Please contact with central air-conditioning management system center, Zhigao regularly, professionals will be sent with paying for checking, draining, adding water, adjustment and other cleaning and maintenance services. Just in case, air conditioner fails down.

Contents

1. 2. 3. 4. 5. 6. 7. 8. 9.

Measures of safety precautions … ……………………………………….. …………… Choosing places of installing…………………………………………………………… Installation of units……………………………………………………………………… Installation of wanderled controller…………………………………………………… Electrical connection ……………………………………………………………… Test of units’ working … …………………………………………………………… Protection and maintenances… ……………………………………………

Names of various part of unit and parameter…… ……………………………………… Instructions of unit function…………………………………………………………

10. Installation of available accessories………………………………………………

Closures chart 1 chart 2 chart 3

1. Measures of Safety Precautions Warning

Dealer or qualified installer is needed.

Installers should be qualified, if install by themselves. Incorrect operations will result in fire, electric shock, injury and leakage.

If the accessories are purchased locally, they should be designated.

Using the specified product may cause fire accidents such as electric shock , leakage. For retails,

professional installers are needed.

Power connections shall comply with the requirements of the local electric company.

By law, reliable grounding is needed. If the ground connection is imperfect, it may result in electric shock.

When the heat pump water heater needs to be moved or re-installed, contact your dealer or professional operators.

Improper installation will result in fire, electric shock, injury, leakage and other accidents. Don’t

make repairs by yourself.

Improper repairs can cause fire, electric shock, injury, leakage and other accidents, be sure to ask

your dealer or professionals for help.

Caution

1. Check the installation of leakage protection.

Leakage protection switch must be installed, if not, it may result in electric shock. 2.Connect the cable correctly.

If the cable is in the wrong way, it may damage the electrical components.

3.The unit can not be set in the combustibles (paint, gasoline, chemical reagents, etc.) near the operation to prevent the risk of fire or explosion. If caught a fire, please immediately turn off the power and put the fire out with a fire extinguisher.

4.Don ’t touch the refrigerant exhausting components to avoid being scalded.

According to the instructions, the unit is required regular maintained to ensure its working. If the unit fails to work, please find the fault and eliminate it ,according to the manual of the "Fault Analysis and Troubleshooting", or contact central air conditioning product management center, identify and eliminate causes of malfunction before rebooting; Don’t do in the case of failure without forcibly boot .

5.If the refrigerant or water happens to leak, please immediately turn off all switches,; For example, the unit can not be operated by the controller, you must turn off the main power to make it stop.

6.Please use the specified capacity fuse, do not use wire, copper wire instead , or it would caught a fire.

2-1 Choosing places for installing

1)Units can be installed on the ground or on a suitable roof, but make sure ventilate as much as possible.

2)Avoid units to be installed in which there’s certain requirements of noise and vibration. 3)The installing places should be avoided where has direct sun shining, and should be far away from the boiler flue or the air which will corrode copper condenser and coils. 4)If the units location are available to unauthorized people ,security measures should be taken, such as setting the fence and so on. This would prevent accidental damage or artificial breakage and it also would prevent the controlling box to be opened to expose the running electrical components

5)The base height of the unit installing should be no less than 100mm.Make sure there’s a drain to let water run out smoothly with no pounding.

6)When installing on the ground, the unit should be placed on a flat concrete base, which should be extended in the permafrost below. Do not place the base unit connecting with the building foundation to avoid noise and vibration transmitting to influence others. The base unit with mounting holes can be tightened with the unit.

7)When the unit is installed on the roof, steels of base units must be strong enough to support the weight of the crew and worker, the unit can be used to support a similar ground-mounted concrete foundation and channel frame. Load-bearing steel tanks with the unit damper mounting holes must be in the same center line, and has sufficient width to install.

8)For special occasional installation requirements , please consult an architect or building contractor or other professional advices.

Caution

When determine the installation positions, water pipes and wiring installation should be considered with no smoking, steaming or other heat draught. What’s more, working noises and cold or hot winds do not affect the surrounding.

2-2Tank installation site selection

1)Places of providing sufficient space for the installation and maintenance.

2)Supporting surface is flat, and can sustain the tank and be fixed to the tank at a vertical direction 3)Places of no corrosive gas leakage.

4)Places are easy to install plumbing and electrical connections

2 The suitable place for installing 2-3 Rooms for installation

1. When installing , resume some place for mending as the following chart, then install the unit

2.Make sure leave enough room for mending .

Pay Caution:

1.If there’s obstruct on the air conditioner unit, please put upper it more than 200mm.

2.If there’s piles of things around the unit , then the distance from its top should be 400 mm 3. If the air conditioner unit is settled in the underground,indoor ,or other closed places, please pay attention to the air circulation around the units , the volume of air for RS-200M/Y should be more than 8000m3/h, so is 12000m3/h for RS-380/TA.

2-4 The moving of air conditioner unit

1. Please use four steel wires of more than & 6mm hanging units to move in .

2. To avoid the units ’ surface to be scratched, deformed, please contact soft things on their

surface with the wire.

3.When it is over, please move away the transporting plate.

2-5 The moving of many air conditioner units

Chart 2.3 RS-200M/Y

Foundation bolts 4/table

Working distance of foundation bolts as the following chart

Chart

3 The units of installation

3-1 The connection of pipe

Caution

During the installing procession, air, dust, and other debris should be not allowed in the piping system. Water heater should be heated before installing inlet and outlet water pipe.

3-1-1 Heat insulation

Insulation materials must be equipped with outlet water pipe 1)Single heat pump water heater connection diagram

2)

multiple heat pump water heaters connection diagram

There are 32 heat pump water heaters at most can be connected one time.

1 cut-off valve 2 Solenoid valve 3. Check valve 4 filters (not less than 60 mesh) 5. Union 6 circulating pump 7. Pressure gauge 8. Thermometer 9. Flow switch 10. Auxiliary heating device (user selectable)

11. Collecting tank (requires higher circulating water outlet port) 12. Collecting tank purge valve 13. Use valve14 pressure switch in parallel flow switch T5: Radiator bulb S1, S2: collecting tank level switch Chart 3.2 RS-200M/Y the choosing of outlet pipe

RS-380M/Ta

the choosing of outlet pipe

并联机组数 the number of parallel units 进水管径 inlet diameter

出水管径outlet diameter


相关文章

  • 地暖系统工作压力是多少?
  • 暖通知识 关于我们企业服务联系我们帮助中心诚聘英才建材网ABOUT US Copyright © 2000-2015 ZHULONG.COM.All Rights Reserved. 京ICP 证号 京公网安备 号 通信地址:北京 百万庄 ...查看


  • 格力空调遥控器使用说明 格力空调遥控器说明详解
  • 您的装修预算是?元 施工费铲除墙面腻子层,滚筒,砂皮等0元 辅料费壁丽宝滑石粉,石膏粉,大理石等0元 计算报价 m2 格力空调遥控器使用说明 格力空调遥控器说明详解15 2015-03-05 14:45:20 我要分享 开启空调机离不开遥控 ...查看


  • 长沙理工大学毕业论文
  • 长沙理工大学继续教育学院 2011 届专科毕业设计(论文) 题目: 轿车空调系统基本工作原理介绍 班 级: 10广本 学 号: 2010BDH04070 姓 名: 张晓东 指导老师: 吴文兵 2012年2月 轿车空调系统基本工作原理介绍 学 ...查看


  • T08012附件格力家用空调安装服务标准
  • 金石电器售后队伍培训文件 KF/08.03-01 家用空调安装服务标准 前言 "今天的服务,决定明天的市场", 客户服务对一个企业来讲至关重要,它是维系企业与客户之间情感的关健纽带,持之以恒地提供优质的服务,能为企业树立 ...查看


  • 空调压缩机的控制原理及维修要点
  • 众所周知,制冷剂和润滑油在空调系统内循环是靠压缩机的驱动,因此说"压缩机是空调系统的心脏"一点也不过分.空调压缩机由发动机前端轮系驱动皮带驱动,传统空调系统由A/C开关控制的电磁离合器结合与分离.目前,许多车辆采用可变排 ...查看


  • 夏季来临 中央空调6大使用误区解析
  • 导语:随着生活水平的不断提高,家用中央空调走进了很多家庭.在夏季来临的日子,空调使用高峰马上就要来了,对于中央空调尚未熟悉的消费者们,在使用中央空调地过程中又存在着哪些误区呢? 家用中央空调的使用注意事项在说明书上都已经介绍得明明白白,可是 ...查看


  • 中央空调系统使用说明书
  • 基于ZigBee的中央空调末端控制系统 使用说明书 中国科学院沈阳自动化研究所 感谢您选购我公司的产品,感谢您对我公司的信任,希望您对我们的工作提 出宝贵意见. 在使用之前请您仔细阅读次说明书, 在阅读之后,请您妥善保管次说明书. 警告!本 ...查看


  • 印刷版电梯专用空调器安装使用说明书
  • 中文DTKCK-25/28/A电梯专用说明书 100g铜板纸说明书 标 记处 数更改文件号签 字日 期 设 计贾 育 隆 标准化阶 段 标 记重 量 比 例校 对审 定审 核批 准S A B 1:1 工 艺 日 期 上海祺泠电器有限公司 注 ...查看


  • 组合式空调机组保养说明书
  • 组合式(恒温恒湿)空调机组 操作规程及维护保养 说 明 书 一.综 述 组合式(恒温恒湿)空调机组设备是一种特殊设备,它的诞生为科学现代化.产品质量的提高和精密设备的有效应用都具有不可忽略的作用,随着经济的发展,科学的进一步提高,人们对组合 ...查看


  • 暖通设计说明(扩初)
  • 七.暖通设计说明 1.工程概况 本项目位于江苏省南通市经济开发区,四至范围:东至富民港河,西至中央路,南至上海路,北至天星横河.建筑性质:住宅及配套公建.总建筑面积279437平方米. 2.设计依据 1). 与本设计有关的主要现行规范.规程 ...查看


热门内容