(工业微生物教育部重点实验室,天津科技大学生物工程学院,天津 300457)

150mm×4.6mm ) 为分摘 要:建立一种测定发酵液中L –色氨酸的高效液相色谱(HPLC ) 方法.以Agilent C18(5 µm,流量为1 mL/min,在278nm 处检测L –色氨酸.该方法离柱,V (0.03%的KH 2PO 4溶液) ﹕V (甲醇) =90﹕10为流动相,平均回收率为98.93%,精密度(RSD ) 为简便、快速、准确,在0.000~1.000g/L范围内线性关系良好(R 2=0.999 9) ,0.247%,可有效应用于发酵液中L –色氨酸含量的测定. 关键词:L –色氨酸;HPLC ;检测

中图分类号:TQ922 文献标志码:A 文章编号:1672-6510(2010) 01-0009-04

Quick Determination of L -Tryptophan in Fermented Broth by HPLC

CHENG Li-kun,XU Qing-yang,XIE Xi-xian,CHEN Ning

(Key Laboratory of Industrial Microbiology,Ministry of Education,College of Biotechnology,

Tianjin University of Science & Technology,Tianjin 300457,China )

Abstract :A method to determine L -tryptophan in fermented broth was developed by high performance liquid 150 mm×4.6 mm) was used with the mobile phase of 0.03% KH2PO 4water chromatography (HPLC ) . An Agilent C18(5 µm,

solution and methanol(the ratio of volume was 90 to 10) . The flow rate was at 1.0 mL/min and the detective wavelength was 278 nm. The method was rapid,accurate and simple with a good linearity(R 2=0.999 9) in the range of 0.000 to 1.000 g/L for L -tryptophan. The average recovery was 98.93% with the relative standard deviation of 0.247%. The method was applicable for L -tryptophan determination in the fermented broth.

Keywords :L -tryptophan ;HPLC ;determination

L –色氨酸(L -tryptophan ) 对人和动物的生长发育

及新陈代谢起重要的作用,被称为第二必需氨基酸,广泛用于医药、食品和饲料等方面[1].目前,微生物 发酵法生产L –色氨酸已经走向实用并且处于主导地位[2],其中微生物发酵法具有产酸高、成本低、质量好等优势,将是未来大规模生产L –色氨酸的首选技 术[3].因此,建立一种快速且准确的测定发酵液中L –色氨酸的方法非常必要.

L –色氨酸的定性和定量测定方法有纸层析法、薄层分析法、比色法、高效液相色谱法、氨基酸分析仪测定法等[4–6].其中最常用的有对二甲胺基苯甲醛比色法和柱前衍生HPLC 法.但这两种方法操作步骤复杂,且分别以50%浓硫酸为显色反应介质和用2,4–二

收稿日期:2009-07-03;修回日期:2009-10-13

硝基氟苯作为衍生剂,实验危险性均很大.由于L –色

氨酸在紫外区有光吸收,因此本文建立了直接利用光电二极管阵列(DAD ) 检测器在278nm 处测定发酵液中L –色氨酸含量的HPLC 法,并与对二甲胺基苯甲醛比色测定法和柱前衍生HPLC 法进行了比较.

1 材料与方法

1.1 仪器与试剂

Agilent 1200型高效液相色谱仪,包括DAD 检测器、梯度四元泵、柱温箱、在线自动脱气器,数据处理由化学工作站完成.L –色氨酸、L –酪氨酸、L –苯丙氨酸,色谱纯,北京索莱宝科技有限公司;甲醇,色谱

基金项目:国家“重大新药创制”科技重大专项课题(2008ZX09401-05) ;国家“十一五”科技支撑计划重点项目(2008BAI63B01) 作者简介:程立坤(1984—),男,山东滨州人,硕士研究生;通信作者:陈 宁,教授,[email protected].

·10·

纯,天津市元立化工有限公司;其他试剂为分析纯. 1.2 方法

对二甲胺基苯甲醛比色法测定:见参考文献[7]. 2,4–二硝基氟苯衍生法测定:见参考文献[8]. HPLC 分析条件:色谱分离柱 Agilent C18(5µm,150mm×4.6mm ) ,流动相 V (0.03% KH2PO 4溶液) ﹕V (甲醇) =90﹕10,流量1.0mL/min,柱温 39℃,进样量20µL,检测波长 278nm .

标准曲线的制作:见参考文献[9]. 样品处理:取1.0mL 发酵液10000r/min离心5min ,取上清液稀释适当倍数使L –色氨酸浓度介于测定方法的检测线性范围内,然后用0.22µm微孔滤膜过滤,所得滤液直接进样测定.

由图2可知,质量浓度为0.100g/L的L –色氨酸

标样在225nm 和278nm 处的保留时间一致.但两者的峰面积不同,分别为11699.9和2902.3,在225 nm 处检测器的输出信号约为278nm 处输出信号的4倍.由于检测器所产生的信号在一定范围内可与被测样品的量呈一定的函数关系,若检测器所产生的信号超出一定范围,输出信号不能与样品量呈一定线性关系[10],则可推断在278nm 处检测L –色氨酸比在225nm 处的线性范围广.图2(a ) 和图2(b ) 中L –色氨酸的峰面积分别占相应色谱图中总峰面积的99.80%和100.00%,说明在225 nm处L –色氨酸标样中的杂质有光吸收,而在278nm 处仅对L –色氨酸标样中的L –色氨酸有光吸收.因此,选择278nm 作为检测波长. 2.2 流动相组成的筛选

采用0.03%KH 2PO 4溶液-甲醇体系作为流动相,为确定二者之间配比,设置体积比为85﹕15、88﹕12、90﹕10和92﹕8四个体系,实验结果见图3.

2 结果与讨论

2.1 检测波长的选择

L –色氨酸是含有吲哚基的中性芳香族氨基酸,在紫外区下具有光吸收.由图1可知,其在225nm 和278 nm处均有吸收峰,则在DAD 检测器中设定两个检测波长分别为225nm 和278nm .质量浓度为0.100g/L的L –色氨酸标样在两种检测波长处的高效液相色谱图如图2所示.

(a ) 85﹕15 (b ) 88﹕

12

图1 L –色氨酸紫外吸收光谱

Fig.1 UV absorption map of L -tryptophan

(c ) 90﹕10 (d ) 92﹕8

图3 不同流动相组成体系的色谱图

Fig.3 HPLC chromatograms of different mobile phases

(a ) 225nm (b ) 278 nm

由图3可知,随着流动相体系中甲醇组分的增加,L –色氨酸的保留时间逐渐缩短.体系a 与体系b 不能将L –色氨酸与其他杂质分开,体系c 与体系d 的分离度(R s ) 分别为2.31、1.69,则选择体系c 作为流动相,即V (0.03% KH2PO 4溶液) ﹕V (甲醇) =90﹕10. 2.3 流动相流量的确定 分别考察流量为0.8、1.0、1.2、1.4mL/min时发

图2 L –色氨酸标准品(0.100 g/L) 高效液相色谱图 Fig.2 HPLC chromatograms of L -tryptophan (0.100 g/L)

·11·

酵液的分离效果,由检测结果可知,流量过小,分析时间延长,柱效降低,而流量过大时,发酵液中物质分离效果差,且由于压力升高而损坏泵头和色谱柱.综合考虑,最终选定流量为1.0mL/min. 2.4 柱温对检测的影响

柱温对氨基酸的分离有较为明显影响,为确定柱 温对发酵液中L –色氨酸分离的影响.在33、36、39、

42℃下各进同一种样品3次,结果见表1.由表1可知,随着柱温的升高,L –色氨酸和邻近L –色氨酸杂质的保留时间均有所减少,同时柱效增强;柱温为39℃时,分离度R s=2.17,两个峰得到完全分离,因此采用柱温为39℃.

表1 温度对L –色氨酸分离的影响

Tab.1 Effect of temperature on chromatographic separationof L -tryptophan

柱温/℃ L –色氨酸保留时间/min

杂质保留时间/min

杂质与L –色氨酸保留时间差/min

(杂质峰宽+L –色氨酸峰宽) 1/2

分离度

33 6.547 36 6.265 39 6.007 42 5.738

6.547 6.265 6.475 6.067

0.000 0.254 0.000 0.248 0.438 0.202 0.329 0.189

2.5 色谱条件确定及其工作曲线

由以上实验确定HPLC 检测L –色氨酸的色谱条件为:流动相V (0.03% KH2PO 4溶液) ﹕V (甲醇) = 90﹕10,流量1.0mL/min,柱温 39℃,进样量20µL,检测波长 278nm .在此条件下,HPLC 检测L –色氨酸标样的色谱图如图

4所示.将不同质量浓度的L –色氨酸标准液在拟定色谱条件下进行测定,3组平行样取其平均值,以L –色氨酸浓度(x ) 为横坐标,峰面积(y ) 为纵坐标作图可得一标准曲线(见图5) .

由图5结果可知,在该色谱条件下L –色氨酸质量浓

度在0.000~1.000g/L线性关系良好. 2.6 精密度实验和回收率实验

将0.100g/L的L –色氨酸标准储备液同浓度平

峰面积RSD 为行3份,当日重复进样6次[11],

0.247%.在已知浓度的发酵液中分别加入一定量的L –色氨酸对照溶液进行回收率实验,每个浓度设3个平行,具体添加量及结果见表2,计算得出其相对回收率为98.93%.

表2 L –色氨酸检测的回收率结果

Tab.2 Results obtained in the recovery test of L -tryptophan

序号

添加量/g

测定量/g

回收率/%

1 0.10 2 0.20 3 0.30 4 0.40 5 0.50 6 0.60

0.099 0.202

0.289 0.402 0.493 0.589

图4 L –色氨酸(0.100g/L) 标样的HPLC 图

Fig.4 HPLC chromatograms of L -tryptophan (0.100g/L)

2.7 发酵液样品的测定及不同检测方法的比较

图6是L –色氨酸发酵液HPLC 测定色谱图.

图5 HPLC 测定L -色氨酸标准曲线

Fig.5 Standard curve of L -tryptophan determination by

HPLC

图6 L –色氨酸发酵液HPLC 测定色谱图

Fig.6 Chromatograms of L -tryptophan fermentation

由图4可见,L –色氨酸的响应时间为6.015min .

由图6可知,色谱柱柱效较高,发酵液样品中某

些其他发酵成分能被检测到且分离效果良好.与标

·12·

准曲线对照测得的发酵液中L –色氨酸含量为32.8g/L,这与对二甲胺基苯甲醛比色法、2,4–二硝基氟苯衍生测定法测得的L –色氨酸含量相一致,从而证明该方法可以准确地检测发酵液中L –色氨酸的含量.由表3可知,该方法与对二甲胺基苯甲醛比色法、2,4–二硝基氟苯衍生测定法相比,线性关系更佳、稳定性好、快速、危险性小、操作步骤简单,且线性范围可达0.000~1.000g/L.

表3 L –色氨酸测定方法比较

Tab.3 Comparison of determination methods for L -tryptophan

方法

本法

对二甲胺基苯甲醛比色法 2,4–二硝基氟苯衍生测定法

检测方法 稀释进样

需沸水浴 需衍生

专用药品 无

对二甲胺基苯甲醛 2,4–二硝基氟苯

回归方程 y =29 750x

y =3.527 5x y =92 467x

相关系数 R =0.999 9R 2=0.997 3R 2=0.999 6

线性范围/(g·L) 0.000~1.000 0.000~

0.100 0.000~0.180

检测时间/min

10 30 60

2.8 其他芳香族氨基酸的干扰

酪氨酸、苯丙氨酸与色氨酸同属于芳香族氨基 酸[12],在278nm 处均有光吸收,则在上述拟定色谱条件下对酪氨酸、苯丙氨酸进行检测,结果如图7 所示.

测定. 参考文献:

[1] 赵春光,程立坤,徐庆阳,等. 微生物法生产L –色氨酸

的研究进展[J ]. 发酵科技通讯,2008,37(4) :34-36.

[2] Kim H U,Kim T Y,Lee S Y. Metabolic flux analysis and

metab olic engineering of microorganisms[J ]. Molecular Biosystems ,2008,4(2) :113-120.

[3] Yanofsky C. Using studies on tryptophan metabolism to

answer basic biological questions[J ]. The Journal of Biological Chemistry,2003,278(13) :10859-10878.

[4] 侯冬岩,回瑞华. 色氨酸和酪氨酸的双波长荧光光谱的

(a ) 酪氨酸 (b ) 苯丙氨酸

研究[J ]. 分析实验室,2001,20(6) :88-89.

[5] 杨晓云,徐汉虹,王立世,等. 色氨酸、半胱氨酸和酪氨

酸的高效毛细管电泳分析[J ]. 分析测试学报,2001,20(3) :15-18.

[6] Widner B,Leb lhub er F,Walli J,et al. Tryptophan

degradation and immune activation in Alzheimer’s disease [J ]. Neural Transm,2000,107(3) :343-353.

[7] 王健,陈宁,徐咏全,等. 发酵液中色氨酸含量的快速测

定[J ]. 食品与发酵工业,2004,30(2) :123-125.

[8] 张昌伟,徐庆阳,刘淑云,等. 2,4–二硝基氟苯衍生法测

定发酵液中组氨酸方法的优化[J ]. 现代化工,2007,27(2) :743-745.

[9] 陈立仁,蒋生祥. 高效液相色谱基础与实践[M ]. 北

京:科学出版社,2001:114-120.

[10] 王宇成. 最新色谱分析检测方法及应用技术实用手册

[M ]. 长春:吉林出版集团,2004:205-212.

[11] 饶志明,徐美娟,沈微,等. 高效液相色谱测定发酵液中

1,2–二羟基丙酮(DHA ) 方法的建立[J ]. 中国生物工程杂志,2008,28(1) :61-64.

[12] Sprenger G A. Aromatic amino acids[J ]. Microbiology

Monographs ,2007,5:93-127.

图7 酪氨酸与苯丙氨酸标样色谱图

Fig.7 HPLC chromatograms of tyrosine and phenylalanine

由图7可知,酪氨酸与苯丙氨酸的保留时间分别为1.982min 和3.967min ,而色氨酸的保留时间为6.015min ,则说明酪氨酸与苯丙氨酸对发酵液中L –色氨酸含量的测定没有干扰,此检测方法适用性强.

3 结 论

HPLC 色谱条件:以Agilent C 18(5µm,150mm× 4.6mm ) 为分离柱,V (0.03% KH2PO 4溶液) ﹕V (甲醇) =90﹕10为流动相,流量为1 mL/min,在278 nm处L –色氨酸可以很好地被检测出来,保留时间为6.015 min,且酪氨酸、苯丙氨酸均对其测定没有干扰,适用性强.与对二甲胺基苯甲醛比色法和柱前衍生 高效液相色谱法相比较,线性更佳、稳定性好、快速、危险性小、操作步骤简单,且线性范围达0.000~1.000g/L,可有效应用于发酵液中L –色氨酸含量的

DOI:10.13364/j.issn.1672-6510.2010.01.009

第25卷 第1期 2010年2月

天津科技大学学报

Journal of Tianjin University of Science & Technology

V ol.25 No. 1 Feb. 2010

HPLC 快速测定发酵液中L –色氨酸

程立坤,徐庆阳,谢希贤,陈 宁

(工业微生物教育部重点实验室,天津科技大学生物工程学院,天津 300457)

150mm×4.6mm ) 为分摘 要:建立一种测定发酵液中L –色氨酸的高效液相色谱(HPLC ) 方法.以Agilent C18(5 µm,流量为1 mL/min,在278nm 处检测L –色氨酸.该方法离柱,V (0.03%的KH 2PO 4溶液) ﹕V (甲醇) =90﹕10为流动相,平均回收率为98.93%,精密度(RSD ) 为简便、快速、准确,在0.000~1.000g/L范围内线性关系良好(R 2=0.999 9) ,0.247%,可有效应用于发酵液中L –色氨酸含量的测定. 关键词:L –色氨酸;HPLC ;检测

中图分类号:TQ922 文献标志码:A 文章编号:1672-6510(2010) 01-0009-04

Quick Determination of L -Tryptophan in Fermented Broth by HPLC

CHENG Li-kun,XU Qing-yang,XIE Xi-xian,CHEN Ning

(Key Laboratory of Industrial Microbiology,Ministry of Education,College of Biotechnology,

Tianjin University of Science & Technology,Tianjin 300457,China )

Abstract :A method to determine L -tryptophan in fermented broth was developed by high performance liquid 150 mm×4.6 mm) was used with the mobile phase of 0.03% KH2PO 4water chromatography (HPLC ) . An Agilent C18(5 µm,

solution and methanol(the ratio of volume was 90 to 10) . The flow rate was at 1.0 mL/min and the detective wavelength was 278 nm. The method was rapid,accurate and simple with a good linearity(R 2=0.999 9) in the range of 0.000 to 1.000 g/L for L -tryptophan. The average recovery was 98.93% with the relative standard deviation of 0.247%. The method was applicable for L -tryptophan determination in the fermented broth.

Keywords :L -tryptophan ;HPLC ;determination

L –色氨酸(L -tryptophan ) 对人和动物的生长发育

及新陈代谢起重要的作用,被称为第二必需氨基酸,广泛用于医药、食品和饲料等方面[1].目前,微生物 发酵法生产L –色氨酸已经走向实用并且处于主导地位[2],其中微生物发酵法具有产酸高、成本低、质量好等优势,将是未来大规模生产L –色氨酸的首选技 术[3].因此,建立一种快速且准确的测定发酵液中L –色氨酸的方法非常必要.

L –色氨酸的定性和定量测定方法有纸层析法、薄层分析法、比色法、高效液相色谱法、氨基酸分析仪测定法等[4–6].其中最常用的有对二甲胺基苯甲醛比色法和柱前衍生HPLC 法.但这两种方法操作步骤复杂,且分别以50%浓硫酸为显色反应介质和用2,4–二

收稿日期:2009-07-03;修回日期:2009-10-13

硝基氟苯作为衍生剂,实验危险性均很大.由于L –色

氨酸在紫外区有光吸收,因此本文建立了直接利用光电二极管阵列(DAD ) 检测器在278nm 处测定发酵液中L –色氨酸含量的HPLC 法,并与对二甲胺基苯甲醛比色测定法和柱前衍生HPLC 法进行了比较.

1 材料与方法

1.1 仪器与试剂

Agilent 1200型高效液相色谱仪,包括DAD 检测器、梯度四元泵、柱温箱、在线自动脱气器,数据处理由化学工作站完成.L –色氨酸、L –酪氨酸、L –苯丙氨酸,色谱纯,北京索莱宝科技有限公司;甲醇,色谱

基金项目:国家“重大新药创制”科技重大专项课题(2008ZX09401-05) ;国家“十一五”科技支撑计划重点项目(2008BAI63B01) 作者简介:程立坤(1984—),男,山东滨州人,硕士研究生;通信作者:陈 宁,教授,[email protected].

·10·

纯,天津市元立化工有限公司;其他试剂为分析纯. 1.2 方法

对二甲胺基苯甲醛比色法测定:见参考文献[7]. 2,4–二硝基氟苯衍生法测定:见参考文献[8]. HPLC 分析条件:色谱分离柱 Agilent C18(5µm,150mm×4.6mm ) ,流动相 V (0.03% KH2PO 4溶液) ﹕V (甲醇) =90﹕10,流量1.0mL/min,柱温 39℃,进样量20µL,检测波长 278nm .

标准曲线的制作:见参考文献[9]. 样品处理:取1.0mL 发酵液10000r/min离心5min ,取上清液稀释适当倍数使L –色氨酸浓度介于测定方法的检测线性范围内,然后用0.22µm微孔滤膜过滤,所得滤液直接进样测定.

由图2可知,质量浓度为0.100g/L的L –色氨酸

标样在225nm 和278nm 处的保留时间一致.但两者的峰面积不同,分别为11699.9和2902.3,在225 nm 处检测器的输出信号约为278nm 处输出信号的4倍.由于检测器所产生的信号在一定范围内可与被测样品的量呈一定的函数关系,若检测器所产生的信号超出一定范围,输出信号不能与样品量呈一定线性关系[10],则可推断在278nm 处检测L –色氨酸比在225nm 处的线性范围广.图2(a ) 和图2(b ) 中L –色氨酸的峰面积分别占相应色谱图中总峰面积的99.80%和100.00%,说明在225 nm处L –色氨酸标样中的杂质有光吸收,而在278nm 处仅对L –色氨酸标样中的L –色氨酸有光吸收.因此,选择278nm 作为检测波长. 2.2 流动相组成的筛选

采用0.03%KH 2PO 4溶液-甲醇体系作为流动相,为确定二者之间配比,设置体积比为85﹕15、88﹕12、90﹕10和92﹕8四个体系,实验结果见图3.

2 结果与讨论

2.1 检测波长的选择

L –色氨酸是含有吲哚基的中性芳香族氨基酸,在紫外区下具有光吸收.由图1可知,其在225nm 和278 nm处均有吸收峰,则在DAD 检测器中设定两个检测波长分别为225nm 和278nm .质量浓度为0.100g/L的L –色氨酸标样在两种检测波长处的高效液相色谱图如图2所示.

(a ) 85﹕15 (b ) 88﹕

12

图1 L –色氨酸紫外吸收光谱

Fig.1 UV absorption map of L -tryptophan

(c ) 90﹕10 (d ) 92﹕8

图3 不同流动相组成体系的色谱图

Fig.3 HPLC chromatograms of different mobile phases

(a ) 225nm (b ) 278 nm

由图3可知,随着流动相体系中甲醇组分的增加,L –色氨酸的保留时间逐渐缩短.体系a 与体系b 不能将L –色氨酸与其他杂质分开,体系c 与体系d 的分离度(R s ) 分别为2.31、1.69,则选择体系c 作为流动相,即V (0.03% KH2PO 4溶液) ﹕V (甲醇) =90﹕10. 2.3 流动相流量的确定 分别考察流量为0.8、1.0、1.2、1.4mL/min时发

图2 L –色氨酸标准品(0.100 g/L) 高效液相色谱图 Fig.2 HPLC chromatograms of L -tryptophan (0.100 g/L)

·11·

酵液的分离效果,由检测结果可知,流量过小,分析时间延长,柱效降低,而流量过大时,发酵液中物质分离效果差,且由于压力升高而损坏泵头和色谱柱.综合考虑,最终选定流量为1.0mL/min. 2.4 柱温对检测的影响

柱温对氨基酸的分离有较为明显影响,为确定柱 温对发酵液中L –色氨酸分离的影响.在33、36、39、

42℃下各进同一种样品3次,结果见表1.由表1可知,随着柱温的升高,L –色氨酸和邻近L –色氨酸杂质的保留时间均有所减少,同时柱效增强;柱温为39℃时,分离度R s=2.17,两个峰得到完全分离,因此采用柱温为39℃.

表1 温度对L –色氨酸分离的影响

Tab.1 Effect of temperature on chromatographic separationof L -tryptophan

柱温/℃ L –色氨酸保留时间/min

杂质保留时间/min

杂质与L –色氨酸保留时间差/min

(杂质峰宽+L –色氨酸峰宽) 1/2

分离度

33 6.547 36 6.265 39 6.007 42 5.738

6.547 6.265 6.475 6.067

0.000 0.254 0.000 0.248 0.438 0.202 0.329 0.189

2.5 色谱条件确定及其工作曲线

由以上实验确定HPLC 检测L –色氨酸的色谱条件为:流动相V (0.03% KH2PO 4溶液) ﹕V (甲醇) = 90﹕10,流量1.0mL/min,柱温 39℃,进样量20µL,检测波长 278nm .在此条件下,HPLC 检测L –色氨酸标样的色谱图如图

4所示.将不同质量浓度的L –色氨酸标准液在拟定色谱条件下进行测定,3组平行样取其平均值,以L –色氨酸浓度(x ) 为横坐标,峰面积(y ) 为纵坐标作图可得一标准曲线(见图5) .

由图5结果可知,在该色谱条件下L –色氨酸质量浓

度在0.000~1.000g/L线性关系良好. 2.6 精密度实验和回收率实验

将0.100g/L的L –色氨酸标准储备液同浓度平

峰面积RSD 为行3份,当日重复进样6次[11],

0.247%.在已知浓度的发酵液中分别加入一定量的L –色氨酸对照溶液进行回收率实验,每个浓度设3个平行,具体添加量及结果见表2,计算得出其相对回收率为98.93%.

表2 L –色氨酸检测的回收率结果

Tab.2 Results obtained in the recovery test of L -tryptophan

序号

添加量/g

测定量/g

回收率/%

1 0.10 2 0.20 3 0.30 4 0.40 5 0.50 6 0.60

0.099 0.202

0.289 0.402 0.493 0.589

图4 L –色氨酸(0.100g/L) 标样的HPLC 图

Fig.4 HPLC chromatograms of L -tryptophan (0.100g/L)

2.7 发酵液样品的测定及不同检测方法的比较

图6是L –色氨酸发酵液HPLC 测定色谱图.

图5 HPLC 测定L -色氨酸标准曲线

Fig.5 Standard curve of L -tryptophan determination by

HPLC

图6 L –色氨酸发酵液HPLC 测定色谱图

Fig.6 Chromatograms of L -tryptophan fermentation

由图4可见,L –色氨酸的响应时间为6.015min .

由图6可知,色谱柱柱效较高,发酵液样品中某

些其他发酵成分能被检测到且分离效果良好.与标

·12·

准曲线对照测得的发酵液中L –色氨酸含量为32.8g/L,这与对二甲胺基苯甲醛比色法、2,4–二硝基氟苯衍生测定法测得的L –色氨酸含量相一致,从而证明该方法可以准确地检测发酵液中L –色氨酸的含量.由表3可知,该方法与对二甲胺基苯甲醛比色法、2,4–二硝基氟苯衍生测定法相比,线性关系更佳、稳定性好、快速、危险性小、操作步骤简单,且线性范围可达0.000~1.000g/L.

表3 L –色氨酸测定方法比较

Tab.3 Comparison of determination methods for L -tryptophan

方法

本法

对二甲胺基苯甲醛比色法 2,4–二硝基氟苯衍生测定法

检测方法 稀释进样

需沸水浴 需衍生

专用药品 无

对二甲胺基苯甲醛 2,4–二硝基氟苯

回归方程 y =29 750x

y =3.527 5x y =92 467x

相关系数 R =0.999 9R 2=0.997 3R 2=0.999 6

线性范围/(g·L) 0.000~1.000 0.000~

0.100 0.000~0.180

检测时间/min

10 30 60

2.8 其他芳香族氨基酸的干扰

酪氨酸、苯丙氨酸与色氨酸同属于芳香族氨基 酸[12],在278nm 处均有光吸收,则在上述拟定色谱条件下对酪氨酸、苯丙氨酸进行检测,结果如图7 所示.

测定. 参考文献:

[1] 赵春光,程立坤,徐庆阳,等. 微生物法生产L –色氨酸

的研究进展[J ]. 发酵科技通讯,2008,37(4) :34-36.

[2] Kim H U,Kim T Y,Lee S Y. Metabolic flux analysis and

metab olic engineering of microorganisms[J ]. Molecular Biosystems ,2008,4(2) :113-120.

[3] Yanofsky C. Using studies on tryptophan metabolism to

answer basic biological questions[J ]. The Journal of Biological Chemistry,2003,278(13) :10859-10878.

[4] 侯冬岩,回瑞华. 色氨酸和酪氨酸的双波长荧光光谱的

(a ) 酪氨酸 (b ) 苯丙氨酸

研究[J ]. 分析实验室,2001,20(6) :88-89.

[5] 杨晓云,徐汉虹,王立世,等. 色氨酸、半胱氨酸和酪氨

酸的高效毛细管电泳分析[J ]. 分析测试学报,2001,20(3) :15-18.

[6] Widner B,Leb lhub er F,Walli J,et al. Tryptophan

degradation and immune activation in Alzheimer’s disease [J ]. Neural Transm,2000,107(3) :343-353.

[7] 王健,陈宁,徐咏全,等. 发酵液中色氨酸含量的快速测

定[J ]. 食品与发酵工业,2004,30(2) :123-125.

[8] 张昌伟,徐庆阳,刘淑云,等. 2,4–二硝基氟苯衍生法测

定发酵液中组氨酸方法的优化[J ]. 现代化工,2007,27(2) :743-745.

[9] 陈立仁,蒋生祥. 高效液相色谱基础与实践[M ]. 北

京:科学出版社,2001:114-120.

[10] 王宇成. 最新色谱分析检测方法及应用技术实用手册

[M ]. 长春:吉林出版集团,2004:205-212.

[11] 饶志明,徐美娟,沈微,等. 高效液相色谱测定发酵液中

1,2–二羟基丙酮(DHA ) 方法的建立[J ]. 中国生物工程杂志,2008,28(1) :61-64.

[12] Sprenger G A. Aromatic amino acids[J ]. Microbiology

Monographs ,2007,5:93-127.

图7 酪氨酸与苯丙氨酸标样色谱图

Fig.7 HPLC chromatograms of tyrosine and phenylalanine

由图7可知,酪氨酸与苯丙氨酸的保留时间分别为1.982min 和3.967min ,而色氨酸的保留时间为6.015min ,则说明酪氨酸与苯丙氨酸对发酵液中L –色氨酸含量的测定没有干扰,此检测方法适用性强.

3 结 论

HPLC 色谱条件:以Agilent C 18(5µm,150mm× 4.6mm ) 为分离柱,V (0.03% KH2PO 4溶液) ﹕V (甲醇) =90﹕10为流动相,流量为1 mL/min,在278 nm处L –色氨酸可以很好地被检测出来,保留时间为6.015 min,且酪氨酸、苯丙氨酸均对其测定没有干扰,适用性强.与对二甲胺基苯甲醛比色法和柱前衍生 高效液相色谱法相比较,线性更佳、稳定性好、快速、危险性小、操作步骤简单,且线性范围达0.000~1.000g/L,可有效应用于发酵液中L –色氨酸含量的


相关文章

  • 膜分离样品前处理技术
  • 第32卷分析化学(FENXIHUAXUE) 研究报告第10期 评述与进展 膜分离样品前处理技术 刘景富 江桂斌3 (中国科学院生态环境研究中心,北京100085) 摘 要 高通量的自动化样品前处理技术正越来越引起分析化学家的关注.综述了常用 ...查看


  • 薄层色谱法在药物分析中的应用
  • 1 薄层色谱法概述 ............................................................................ 2 1.1 定义 ........................ ...查看


  • 食品中蛋白质测定方法的比较
  • 广西质量监督导报2008第11期总第95期 食品中蛋白质测定方法的比较 李伟1 王鑫1 王刚1 李丽莉2佟长青1金桥1 (1.辽宁省水产品加工及综合利用重点开放实验室,大连水产学院食品工程学院,辽宁大连116023:2.黑龙江大学生命科学与 ...查看


  • 酸乳中有机酸的测定方法
  • 辽宁经济管理干部学院 辽宁经济职业技术学院 毕 业 论 文 题 目 酸乳中有机酸的测定方法 姓 名 所在系部 生物工程系 专业班级 食品生物技术 学 号 指导教师 日 期 2010年 4 月 13 日 酸乳中有机酸的测定方法 10食品班 王 ...查看


  • 荧光分析法在食品分析中的应用
  • 2007年8月第8期(总第105期) 广西轻工业 GUANGXIJOURNALOFLIGHTINDUSTRY 食品与生物 荧光分析法在食品分析中的应用 黄润均1,蔡卓2,李斯光 2 (1.桂林工学院南宁分院,广西南宁530001:2.广西大 ...查看


  • 蝉花生物活性物质研究
  • 蝉花生物活性物质研究 盖 悦 2010.01.26 蝉花(Cordyceps cicadae) 属虫生性药用真菌,是我国传统名贵中药材,又名蝉蛹草.蝉茸.胡蝉.蜩等,是蝉在土中的若虫被麦角菌科真菌的分生孢子寄生致死的带菌尸体,其在头部长菌丝 ...查看


  • 氨基酸分析方法的研究进展
  • 第4期2013年8月 N o. 4 A u g. 2013现代科学仪器 Modern Scientific Instruments 55 氨基酸分析方法的研究进展 江海风1 马品一2 金 月2 冯旭东2 王兴华2 (1中国船舶重工集团公司第 ...查看


  • 拮抗菌抗菌谱及发酵液拮抗能力测定的新方法
  • 第17卷第1期:55生 物 技 术Vol 17, No 1:55 2007年2月BIOTECHNOLOGY Feb 2007用0. 45 m 的滤膜过滤, 取1. 0mL 滤液进行适当稀释即得到待测液. HPLC [12]色谱柱(酸柱) : ...查看


  • 蛋白质与酶工程
  • 酶工程就是酶学理论与化学工程相结合,并在一定的反应装置中利用酶的催化特性,将原料转化为产物,是酶制剂大批量生产和应用的技术. 主要内容:酶的生产.提取与分离纯化.酶分子修饰.酶分子定向进化.酶固定化.酶非水相催化.酶反应器以及应用等. 蛋白 ...查看


热门内容